TM-9-2350-261-20-2

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 2 OF 4

  TM-9-2350-261-20-2 - Page 134 of 1008

TM 9-2350-261-20-2
REPLACE MASTER SWITCH PANEL ASSEMBLY (EARLY SLAVE RECEPTACLE)
(ALL EXCEPT M577A2) — Continued
0223 00
3.
Remove screw (8), locknut (9), washer (10), and ground lead (11) from instrument panel strut (12). Discard locknut.
4.
Remove circuit 49 lead (13), circuit 6 lead (14), and two grommets (15) from master switch panel assembly (6). Discard
grommets.
5.
Remove nut (1), screw (2), two lockwashers (3), and circuit 49 lead (4) from auxiliary power receptacle lead (5). Discard
lockwashers.
6.
Remove locknut (6), screw (7), circuit 6 lead (8), circuit 2 lead (9), and circuit 400 lead (10) from bus bar (11). Discard
locknut.
NOTE
For all carriers with 200 amp generator, do Step 7.
7.
Remove nut (12), lockwasher (13), and circuit 2A lead (14) from master switch terminal (15). Discard lockwasher.
8.
Remove master switch panel (16) from carrier.
0223 00-2


Back to Top