TM 9-2350-261-20-2
REPLACE MASTER SWITCH PANEL ASSEMBLY (EARLY SLAVE RECEPTACLE)
(M577A2 AND M1068 ONLY) — Continued
0224 00
3.
Install three new grommets (7) and circuit 37A lead (8), circuit 38 lead (9), circuit 38A lead (10) leads in master switch
panel assembly (1).
4.
Connect circuit 37A lead (8) to circuit breaker (11).
5.
Connect circuit 38 lead (9) and circuit 38A lead (10) to dome light switch (12).
6.
Connect utility outlet lead (13) to circuit 37 lead (14).
7.
Install two new grommets (15), wiring harness (16), and circuit 59 lead (17) in master switch panel (1).
8.
Connect wiring harness (16) to blower switch (18) and to circuit 37B lead on circuit breaker (19).
9.
Connect circuit 59 lead (17) to blower switch (18).
10. Install a new grommet (1) and wiring harness (2) in master switch panel (3).
11. Connect wiring harness (2) to circuit 38E lead (4). Connect circuit 10 lead (5) on circuit breaker (6). Connect circuit 10
lead (7) on dome light switch (8).
12. Install a new grommet (9) and circuit 6 lead (10) in master switch panel (3).
NOTE
Step 6 is for 200 amp generator system only. All other steps are common.
13. For 200 amp generator system, install circuit 2A lead (11) on top terminal of master switch (12). Secure with new
lockwasher (13) and nut (14).
14. Install circuit 6 lead (10), circuit 2 lead (15), and circuit 400 lead (16) on bus bar (17). Secure with screw (18) and
nut (19).
15. Install new grommet (20) and circuit 49 lead (21) in master switch panel assembly (3).
0224 00-6