TM-9-2350-261-20-2

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 2 OF 4

  TM-9-2350-261-20-2 - Page 141 of 1008

TM 9-2350-261-20-2
REPLACE MASTER SWITCH PANEL ASSEMBLY (EARLY SLAVE RECEPTACLE)
(M577A2 AND M1068 ONLY) — Continued
0224 00
17. Disconnect circuit 28 lead (3), circuit 29 lead (4), and circuit 30 lead (5) from fuel selector switch (6).
18. Remove circuit 28 lead (3), circuit 29 lead (4), and circuit 30 lead (5) and three grommets (2) from master switch panel
(1). Discard grommets.
19. Remove master switch panel assembly (1) from carrier.
INSTALLATION
1.
Install three new grommets (2) and circuit 28 lead (3), circuit 29 lead (4), and circuit 30 lead (5) in master switch panel
(1).
2.
Connect circuit 28 lead (3), circuit 29 lead (4), and circuit 30 lead (5) to fuel selector switch (6).
022400-5