REPLACE MASTER SWITCH TO DISTRIBUTION BOX WIRE ASSEMBLY (CIRCUIT
49 LEAD) (ALL EXCEPT M577A2 AND M1068) — Continued
0225 00
6.
Install master switch panel (3) on distribution box (4). Secure with eight screws (16), washers (17), and new locknuts
(18).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
2.
Turn MASTER SWITCH to ON (see your -10).
3.
Check that
master switch
on
indicator light comes on ( see your - 10).
4.
Turn MASTER SWITCH to OFF (see your -10).
END OF TASK
0225 00-6