NOTE
If replacing generator, do Steps 8 - 10.
8.
Remove three screws (10) and washers (11) securing pulley (12) and bushing (13) to generator shaft (14).
9.
Use three screws (10) to separate pulley (12) and bushing (13). (Install three screws in three threaded holes of pulley.
Tighten screws until you are able to separate pulley from bushing.)
10. Remove pulley (12) and bushing (13) from generator shaft (14). Remove key (15) from generator shaft.
022700-3