  TM-9-2350-261-20-2 - Page 147 of 1008

TM 9-2350-261-20-2
REPLACE MASTER SWITCH TO DISTRIBUTION BOX WIRE ASSEMBLY (CIRCUIT
49 LEAD) (ALL EXCEPT M577A2 AND M1068) — Continued
0225 00
4.
Remove screw (15), washer (16), and circuit 49 lead (9) from distribution box bus bar(17)
.
5.
Remove circuit 49 lead (1) with two grommets (2) from master switch panel (3) and distribution box (4). Discard
grommets.
REPAIR
1.
Check circuit 49 lead for continuity. Use multimeter. Replace bad lead.