TM 9-2350-261-20-2
REPLACE MASTER SWITCH PANEL ASSEMBLY (EARLY SLAVE RECEPTACLE)
(M577A2 AND M1068 ONLY) — Continued
0224 00
16. Install circuit 49 lead (21) on bottom terminal of master switch (12). Secure with washer (22) and nut (23).
17. Connect wiring harness (24) leads (25), (26), and (27) to three circuit breakers (28), (29), and (30).
18. Replace gasket between master switch panel and distribution box, if damaged (WP 0266 00).
022400-7