TM 9-2350-261-20-2
REPLACE MASTER SWITCH PANEL ASSEMBLY (EARLY SLAVE
RECEPTACLE) (ALL EXCEPT M577A2)
0223 00
THIS WORK PACKAGE COVERS:
Removal (page 0223 00-1).
Installation (page 0223 00-3).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Materials/Parts
Grommet (2)
Lockwasher (3)
Locknut (2)
Locknut (8)
Personnel Required
Unit Mechanic
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Battery ground lead disconnected (WP 0294 00)
Infrared power supply cable disconnected from master
switch panel (WP 0291 00)
REMOVAL
1.
Disconnect circuit 37 lead (1) from connector (2).
2.
Remove eight locknuts (3), washers (4), and screws (5). Separate master switch panel assembly (6) from distribution
box (7). Discard locknuts.
022300-1