TM 9-2350-261-20-2
REPLACE MASTER SWITCH PANEL ASSEMBLY (EARLY SLAVE RECEPTACLE)
(M577A2 AND M1068 ONLY) — Continued
0224 00
10. Disconnect wiring harness (20) from blower switch (21) and circuit 37B on circuit breaker (22).
11. Disconnect circuit 59 lead (23) from blower switch (21).
12. Remove circuit 59 lead (23), wiring harness (20), and two grommets (24) from master switch panel assembly (25).
Discard grommets.
13. Disconnect utility outlet lead (26) from circuit 37 lead (27).
14. Disconnect circuit 37A lead (28) from circuit 37A lead on circuit breaker (29).
15. Disconnect circuits 38A lead (9) and 38 lead (10) from dome light switch (12).
16. Remove circuits 37A (8), 38 (10), 38A (9) leads and three grommets (7) from master switch panel (1). Discard
grommets.
0224 00-4