TM 9-2350-261-20-2
REPLACE MASTER SWITCH TO DISTRIBUTION BOX WIRE ASSEMBLY (CIRCUIT
49 LEAD) (ALL EXCEPT M577A2 AND M1068) — Continued
0225 00
2.
Early slave receptacle only: remove locknut (6), two washers (7), screw (8), and circuit 49 lead (9) from circuit 50 lead
terminal (10). Discard locknut.
3.
Late slave receptacle only: remove locknut (11), circuit 50 lead (12), and circuit 49 lead (13) from master switch
terminal (14). Discard locknut.
0225 00-2