TM-9-2350-261-20-2

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 2 OF 4

  TM-9-2350-261-20-2 - Page 148 of 1008

TM 9-2350-261-20-2
REPLACE MASTER SWITCH TO DISTRIBUTION BOX WIRE ASSEMBLY (CIRCUIT
49 LEAD) (ALL EXCEPT M577A2 AND M1068) — Continued
0225 00
INSTALLATION
1.
Install two new grommets (2) on circuit 49 lead (1).
2.
Route circuit 49 lead (1) through distribution box (4) and master switch panel (3). Install grommets (2) in box and panel.
0225 00-4