TM 9-2350-261-20-2
REPLACE MASTER SWITCH PANEL ASSEMBLY (LATE SLAVE RECEPTACLE)
(ALL EXCEPT M577A2 AND M1068) — Continued
0222 00
2.
Install circuit 49 lead (15) on bus bar (16). Secure with new lockwasher (14) and screw (13).
3.
Install new grommet (8) on circuit 6 lead (5). Route lead into master switch panel (9) and secure grommet.
4.
Install circuit 6 lead (5), circuit 2 lead (3), and circuit 400 lead (4) on conductor bus (7). Secure with screw (1) and new
locknut (2).
5.
Install circuit 2A lead (6) on master switch post (12). Secure with new lockwasher (11) and nut (10).
0222 00-4