TM 9-2350-261-20-2
REPLACE GENERATOR AND ADJUSTMENT LINKAGE (100 AMP
GENERATOR ONLY) — Continued
0227 00
NOTE
Use straight edge across face of both pulleys to assist in proper alignment.
8.
To obtain correct alignment, adjust the position of the generator mounting bracket (11) before you tighten the screws
in the slotted holes. Align pulley (12) on generator (13) withdrivepulley(14)ontransfergearcasetowithin1/8inch
(3.2 mm), then tighten screws (11).
9.
Place spacer (15) and rod end (7) on bracket (2). Secure with screw (16) and new locknut (17).
10. Place spacer (18) and rod end (8) on generator (13). Secure with screw (19) and new locknut (20).
11. Connect cable (21) to generator (13).
FOLLOW-THROUGH STEPS
1.
Connect battery ground lead (WP 0294 00).
2.
Install generator drive belts (WP 0226 00).
3.
Check generator output for proper operation.
4.
Stop/shutdown engine (see your -10).
5.
Install power plant rear access panels and support (WP 0431 00).
END OF TASK
0227 00-6