TM 9-2350-261-20-2
ADJUST VOLTAGE REGULATOR (100/200 AMP GENERATOR)
0229 00
THIS WORK PACKAGE COVERS:
Adjustment (page 0229 00-1)
.
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
Digital Multimeter (WP 0780 00, Item 43)
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Personnel Required
Unit Mechanic
References
TM 9-6140-200-14
Equipment Condition
Engine stopped/shutdown (see your -10)
Carrier blocked (see your -10)
ADJUSTMENT
NOTE
Check batteries to make sure they are fully charged. See TM 9-6140-200-14.
1.
Remove access screw (1) from regulator (2).
2.
Start engine and allow to run for about 20 minutes with service headlights on (see your -10).
3.
Turn off service headlights (see your -10).
4.
Set multimeter to read voltage on the 50 V dc scale.
5.
Remove receptacle cap (3).
022900-1