TM 9-2350-261-20-2
REPLACE REGULATOR ASSEMBLY (100/200 AMP GENERATOR)
0230 00
THIS WORK PACKAGE COVERS:
Removal (page 0230 00-1).
Repair or Replacement (page 0230 00-2).
Installation (page 0230 00-3).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Materials/Parts
Lockwasher (8)
Lockwasher (8)
Lockwasher
Personnel Required
U nit M echanic
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Battery ground lead disconnected (WP 0294 00)
REMOVAL
1.
Disconnect two cannon plugs (1) and (2) from regulator (3).
023000-1