TM-9-2350-261-20-2

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 2 OF 4

  TM-9-2350-261-20-2 - Page 177 of 1008

TM 9-2350-261-20-2
REPLACE GENERATOR FIELD SWITCH
0232 00
THIS WORK PACKAGE COVERS:
Removal (page 0232 00-1).
Repair or Replacement (page 0232 00-1).
Installation (page 0232 00-2).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanic’s Tool Kit (WP 0780 00, Item 29)
Materials/Parts
Sealing compound (WP 0782 00, Item 60)
Personnel Required
Unit Mechanic
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Rear power plant access panel removed
(see your -10)
REMOVAL
1.
Disconnect circuit 1A/1B lead (1) from generator field switch (2).
NOTE
Earlier switches may have a threaded pipe plug without a head or no plug at all. Discard the
pipe plug with the switch. Do not reuse pipe plug because it can be installed too deeply and
short out the new switch.
2.
Remove switch (2) from tee (3) on secondary fuel filter (4).
REPAIR OR REPLACEMENT
1.
Check circuit lead. Replace worn or cracked lead and damaged connector (WP 0312 00, WP 0313 00, or WP 0314 00).
023200-1


Back to Top