TM-9-2350-261-20-2

CARRIER, M113A2, M577A2, M1064, M1068, M1059 AND M901A1

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL - VOLUME 2 OF 4

  TM-9-2350-261-20-2 - Page 206 of 1008

TM 9-2350-261-20-2
REPLACE CIRCUIT BREAKER — Continued
0239 00
INSTALLATION
1.
Place circuit breaker (3) on rear of instrument panel. Secure with two screws (5) and new locknuts (4).
2.
Connect circuit 27 lead (2) and circuit 10 lead (1) to circuit breaker (3).
FOLLOW-THROUGH STEPS
1.
Install instrument panel (WP 0238 00).
2.
Connect battery ground lead (WP 0294 00).
3.
Turn MASTER SWITCH to ON, light should come on for proper installation of circuit breaker (see your -10).
4.
Turn MASTER SWITCH to OFF (see your -10).
END OF TASK
0239 00-2