TM 9-2350-261-20-2
REPLACE DISTRIBUTION BOX ASSEMBLY FOR 100 AMP GENERATOR
SYSTEM (M901A1 ONLY) — Continued
0268 00
10. Install two new grommets (1) and (2), cable assembly W8 lead (3), and circuit 49 lead (4) in distribution box (5). Install
circuit 49 lead and cable assembly W8 lead on bus bar (6). Secure with new lockwasher (7) and screw (8).
11. Install new grommet (9) and circuit 10, 14, 15, and 27E lead (10) in distribution box (5). Install circuit 10, 14, 15, and
27E lead and circuit 450A lead (11) on bus bar (6). Secure with new lockwasher (12) and screw (13).
12. Install new grommet (14) and circuit 6 lead (15) in distribution box (5). Install circuit 6 lead and cable assembly W8
leads (3) on bus bar (6). Secure with new lockwasher (16) and screw (17).
026800-5