TM 9-2350-261-20-2
REPLACE DISTRIBUTION BOX ASSEMBLY FOR 100 AMP GENERATOR
SYSTEM (M901A1 ONLY) — Continued
0268 00
4.
Remove screw (1), lockwasher (2), and circuit 3 lead (3) from circuit breaker (4). Remove circuit 3 lead (3) and grommet
(5) from distribution box (6). Discard grommet and lockwasher.
5.
Remove circuit 450 lead (7) from circuit breaker (8). Remove circuit 450 lead (7) and grommet (9) from distribution
box (6). Discard grommet.
6.
Disconnect circuit 450B lead (10) from circuit breaker (11). Remove circuit 450B lead (10) and grommet (12) from
distribution box (6). Discard grommet.
NOTE
If bilge pump circuit breakers must be removed, see WP 0327 00 for removal. If bilge pump
circuit breakers are not to be removed, go to Step 10.
7.
Remove screw (13), lockwasher (14), and circuit 450C lead (15) from bus bar (16). Discard lockwasher.
8.
Disconnect circuit 450C lead (15) from circuit breaker (17). Remove circuit 450C lead (15) from distribution box (6).
9.
Disconnect circuit 450A lead (18) from circuit breaker (19). Remove circuit 450A lead (18) from distribution box (6).
10. Remove circuit 2 lead (20) and grommet (21) from distribution box (6). Discard grommet.
11. Remove circuit 400 lead (22) and grommet (23) from distribution box (6). Discard grommet.
0268 00-2