REPLACE DISTRIBUTION BOX ASSEMBLY FOR 200 AMP GENERATOR SYSTEM
(M577A2 AND M1068 ONLY) — Continued
0266 00
WARNING
Adhesive, primer, sealant compounds, and isopropyl alcohol are toxic and flammable. These
compounds are toxic to eyes, skin, and respiratory tract. Continued exposure can make you
dizzy and irritate your eyes and throat.
Always use in well ventilated areas, away from heat, sparks, and flames. Do not breathe fumes.
Do not allow into contact with skin and eyes. Use goggles or face shield and protective gloves.
14. Apply one coat of adhesive to cleaned mounting surface of distribution box (1) and one side of new gasket (2).
15. Install new gasket (2) on coated mounting surface of distribution box (1).
FOLLOW-THROUGH STEPS
1.
Install master switch panel (WP 0224 00).
2.
Connect battery ground lead (WP 0294 00).
3.
Start engine (see your -10). Check that distribution box is operable.
4.
Stop engine(seeyour-10)
.
END OF TASK
0266 00-6