TM 9-2350-261-20-2
REPLACE DISTRIBUTION BOX ASSEMBLY FOR 100 AMP GENERATOR
SYSTEM (M577A2 ONLY) — Continued
0267 00
13. Remove five screws (1), lockwashers (2), and distribution box (3) from hull. Discard lockwashers.
14. Remove gasket (4) from distribution box (3). Discard gasket.
INSTALLATION
1.
Install distribution box (3) on hull. Secure with five new lockwashers (2) and screws (1).
026700-3