TM 9-2350-261-20-2
REPLACE COOLING FAN ASSEMBLY — Continued
0216 00
WARNING
Hanging loads, heavy parts, and overhead equipment can fall unexpectedly and kill or injure
you.
Stay clear of hanging loads, heavy parts, and overhead equipment. Use correct lifting devices.
Always have helper guide heavy parts and equipment.
1.
Attach sling and suitable lifting device of at least 150 lbs (45 kg) capacity to fan assembly.
2.
Remove six screws (1) and washers (2) securing fan assembly (3) to power plant grill (4).
3.
Lift fan assembly (3) from power plant grill (4) and place fan assembly on work bench or a flat wooden board.
4.
Remove fan drive pulley (5) from fan assembly (3) (WP 0214 00).
5.
Remove plug (6) and packing (7) from fan drive right angle gearbox (8). Use suitable container and drain gearbox
(WP 0120 00).
6.
If decal (9) is damaged or unreadable, remove it.
0216 00-2