TM 9-2350-277-20-4
REPLACE TURBINE ACCESS DOOR HINGES (M58 ONLY) — Continued
0487 00
REMOVAL
WARNING
Do not remove screws securing door to hull. It may fall and injure personnel. Tag door handle
to warn those who want access to turbine compartment.
1.
Remove eight screws (1), washers (2), and two hinges (3) from carrier and turbine access door (4).
2.
Remove two cotter pins (5), shoulder pins (6), and washers (7) from four hinge halves (8). Discard cotter pins.
0487 00-2