TM 9-2350-277-34
INSTALL CAPSTAN KIT (M1059A3 ONLY) — Continued
0086 00
12. Weld supports (1) and (2) to top plate of carrier as marked in Step 10 in accordance with TM 9-237. Use electrode type
5356.
13. Clean weld area and apply touch-up paint to repaired area (see TM 43-0139).
14. Unscrew two retainers (3) to remove two drums (4) from two adapters (5).
15. Place one drum (4) over stowage support (1). Place the other drum (4) over stowage support (2). Secure with two
retainers (3).
Change 3
0086 00-3
8.
Makesureretainer(5)isinstalledindrum(6)withpin(7).
9.
Installdrum(6)onadapter(3).Securewithretainer(5).
10.Measureandmarkthecorrectpositionsforthesmallerstowagesupport(1)andforthelargersupport(2)ontopofcarrier.
NOTE
Allweldsizesareminimum.Donotexceed1/16inch(2mm)overspecifiedsizes.
11. Remove all paint, anodize, and debris from surfaces under stowage supports to be welded.