TM-9-2350-311-20-2

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR CAB, ARMAMENT, SIGHTING AND FIRE CONTROL, ELEVATING AND TRAVERSING SYSTEMS AND ASSOCIATED COMPONENTS

DECEMBER 1993

  TM-9-2350-311-20-2 - Page 325 of 828

TM 9–2350–311–20–2
Change 2
6–9
6–3
POWER PACK, HYDRAULIC (DRAINING, FILLING AND CHARGING)
This task covers:
a.
Discharging Pressure
b.
Draining Fluid
c.
Filling
d.
Charging
INITIAL SETUP
Tools
Artillery and turret mechanic’s tool kit
(SC 5180–95–CL–A12)
Drain pan (item 8, Appx H)
Utility pail (item 7, Appx H)
Materials/Parts
Caps and plugs (item 7, Appx D)
Hydraulic fluid, OHT (item 21, Appx D)
Equipment Condition
Tow cable and cab access cover removed (para 14–11)
Cab traverse lock locked (TM 9–2350–311–10)
Vehicle MASTER switch to OFF (TM 9–2350–311–10)
CAB POWER switch to OFF (TM 9–2350–311–10)
TRAVERSE CONTROL switch in MANUAL position
(TM 9–2350–311–10)
a.
Discharging Pressure
CAUTION
All hydraulic lines and ports must be capped to prevent contaminants from entering the hydraulic
system and causing internal damage to hydraulic components.
1
Disconnect wire 645 (1) at pressure switch (2) or at quick disconnect (3) near pressure gage (4).
4
1
3
2


Back to Top