TM 9–2350–311–20–2
Change 2
6–3
6–1
GAGE ASSEMBLY, SIGHT
This task covers:
a.
Removal
b.
Disassembly
c.
Assembly
d.
Installation
INITIAL SETUP
Tools
Artillery and turret mechanic’s tool kit
(SC 5180–95–CL–A12)
Utility pail (item 7, Appx H)
Materials/Parts
Caps and plugs (item 7, Appx D)
Lockwasher (item 80, Appx G)
Lockwashers (2) (item 79, Appx G)
Equipment Condition
Discharge hydraulic pressure (para 6–3)
Tow cable and cab access cover removed (para 14–11)
a.
Removal
CAUTION
All hydraulic lines and ports must be capped to prevent contaminants from entering the hydraulic
system and causing internal damage to hydraulic components.
NOTE
Dispose of hydraulic fluid in accordance with local regulations.
1
Drain hydraulic fluid from sight gage (1) by removing plug (2) and turning pointer handle (3) to DRAIN posi-
tion. Drain into utility pail.
1
2
3