TM 9–2350–311–20–2
8–27
NOTE
Step 3 applies to M109A4/M109A5 howitzers only.
3
Connect connector (4) at NBC control box.
4
Connect connector (3), wire 100, at gunner’s selector switch box assembly.
5
Connect lug terminals (2) at contact arm assemblies.
6
Connect female connector (1), wire 100, at power relay box assembly.
3
2
3
2
1
4
2
2
2
2
1
1
2
2
2
3
5 CONTACT ARM ASSEMBLY ON M109A4/M109A5 HOWITZERS
5 CONTACT ARM ASSEMBLY ON M109A2/M109A3 HOWITZERS
3 CONTACT ARM ASSEMBLY ON M109A3 HOWITZERS