TM 9–2350–311–20–2
17–5
b.
Disassembly
WARNING
Be certain MASTER switch is in OFF position when working on electrical system to avoid electrical
shock and burns.
1
Turn light lens (14) counterclockwise and remove.
2
Remove incandescent lamp (15) from M3 electrical air heater (2).
NOTE
Be sure knob is in OFF position before removing.
3
Loosen screw (16) and pull knob (17) off M3 electrical air heater (2).
c.
Assembly
1
Install incandescent lamp (15).
2
Install light lens (14) in M3 electrical air heater (2) by turning clockwise.
3
Position knob (17) on M3 electrical air heater (2) in the OFF position and tighten screw (16).
14
15
17
2
16