TM 9–2350–311–20–2
17–12
17–3 M2A2 AIR PURIFIER AND BRACKET — CONTINUED
f.
Installation
1
Position angle bracket (14) on right front cab wall and secure with four new lockwashers (13) and four cap
screws (12).
2
Install ground lead (5) on top of M2A2 air purifier (9) using new lockwasher (8) and machine screw (7).
3
Lift strap (11), install M2A2 air purifier (9) in angle bracket (14) and secure with strap.
4
Install remaining end of ground lead (5) at M27 periscope box (6) using new lockwasher (4) and cap screw
(3).
5
Plug NBC power lead assembly (10) into connector (19) on lower side of M2A2 air purifier (9).
6
Connect four hoses (1) to air outlets (2).