TM 9–2350–311–20–2
17–4
17–2 M3 ELECTRICAL AIR HEATER — CONTINUED
a.
Removal — Continued
2
Loosen hose clamp (3) and disconnect hose (4) from adapter (5) in inlet port (6) of M3 electrical air heater
(2).
3
Loosen hose clamp (7) and disconnect hose (8) from adapter (9) in outlet port (10) of M3 electrical air heat-
er (2).
NOTE
Section chief’s station requires removal of a retaining strap, and cannoneer no. 1’s station requires
removal of a retaining strap and a washer when removing M3 electrical air heaters.
4
Remove four cap screws (11), four lockwashers (12), M3 electrical air heater (2), and four lockwashers (13)
from cab ceiling. Discard all lockwashers.
5
Remove adapters (5 and 9).
13
1
2
6
3
4
8
7
9
5
12
11
5
9
2
10