TM-9-2350-311-20-2

HOWITZER, MEDIUM, SELF-PROPELLED, 155MM; M109A2, M109A3, M109A4 AND M109A5

TECHNICAL MANUAL; UNIT MAINTENANCE MANUAL FOR CAB, ARMAMENT, SIGHTING AND FIRE CONTROL, ELEVATING AND TRAVERSING SYSTEMS AND ASSOCIATED COMPONENTS

DECEMBER 1993

  TM-9-2350-311-20-2 - Page 644 of 828

TM 9–2350–311–20–2
17–6
17–2 M3 ELECTRICAL AIR HEATER — CONTINUED
d.
Installation
WARNING
Turn CAB POWER and MASTER switches to OFF before connecting electrical leads to avoid elec-
trical shock and burn.
NOTE
M3 electrical air heaters at all stations except the section chief’s must have heater kit assembled to
them. Perform steps 1 through 4 to assemble kit. Section chief’s M3 electrical air heater does not
need the kit applied; proceed to step 5.
1
Remove four screws (18), control unit (19), and plate mount (20) from heater unit (21) and set aside.
2
Position angle bracket (22) on heater unit clamp (23) so outlet port (10) is to the right of the angle of the an-
gle bracket. Secure using four screws (24).
3
Aline three holes on plate mount (20) with three holes on angle bracket (22) and install screw (25) in center
hole.
4
Secure control unit (19) to plate mount (20) using four screws (18).
24
22
20
25
18
21
23
19
10


Back to Top