TM 9–2350–311–20–2
19–29
13
Slowly open angle valve (12) to release pressure in nitrogen charging assembly (7). Remove angle valve
(10) from valve (5).
14
Install air valve cap (3) on valve (5).
15
Close shutoff valve (13) on nitrogen cylinder (9).
16
Remove nitrogen charging assembly (7) from nitrogen cylinder (9) and secondary accumulator assembly
(6).
17
Install gage (8) on nitrogen charging assembly (7).
18
Install retaining strap (2) and two cap screws (1).
8
11
14
15
2
1
3
6
13
9
7
12
5
4
10