TM 9-2350-311-34-2
29
Install two new preformed packings (5) and recoil cylinder drain plugs (4) at rear of each recoil cylinder (3).
30
Recharge recuperator with nitrogen (TM 9-2350-311-20-2).
31
Close bleeder "T" (2) at front of left variable recoil cylinder (3).
32
Remove hose from bleeder “T" (2).
33
Close accumulator replenisher right manifold bleeder plug (1).
34
Recharge replenisher hydraulic system with hydraulic fluid (TM 9-2350-311-20-2).
NOTE
Check variable recoil assembly for hydraulic leaks.