TM 9-2350-311-34-2
14-2.1
M140 ALINEMENT DEVICE MOUNT AND BRACKET (INDIRECT FIRE)
—
Continued
d. Installation — Continued
5
Install M140 alinement device (TM 9-2350-311-10).
6
With an observer viewing through the M117/M117A2 panoramic telescope, aline M140 alinement device
mount (3) until the reticle of the M140 alinement device coincides with the M117/M117A2 panoramic tele-
scope reticle, as shown, by loosening and tightening cap screws (1). Torque cap screws to 20-25 lb-ft
(27-34 N·m) when alinement is met.
7
Remove M140 alinement device (TM 9-2350-311-10).
14-4.6
Change 2