TM-9-2540-207-14-P

HEATER, VEHICULAR COMPARTMENT, MODEL: A20

TECHNICAL MANUAL; OPERATOR, FIELD, AND SUSTAINMENT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST

JULY 2007

  TM-9-2540-207-14-P - Page 110 of 288

TM 9-2540-207-14&P
5-66
Vent Sensor Assembly (Applies to all Design Iterations) (Continued)
5.8.3.2 Installation
Note: Vent Sensor MUST be aligned as shown in Figure 5.8-5 Vent Sensor
Assembly so that Vent Sensor wire lays in the proper channel of the Heat
Exchanger.
1.
Install Vent Sensor onto the Heat Exchanger ensuring that the three (3) screw holes line
up and the Vent Sensor wire is located on the proper side of the Heat Exchanger.
Note: Heat Shield must be located on inside face of Vent Sensor.
2.
Using a #2 cross-tip screwdriver, secure the Vent Sensor to the Heat Exchanger with
three (3) screws.
3.
Place the Vent Sensor wire into the channel on the side of the Heat Exchanger ensuring
that there is no strain on the connections at the Vent Sensor end.
Lightly re-crimp
channel to secure Vent Sensor wire.
Be careful not to damage the wire during this
procedure.
4.
Using a 5/16" socket or nut driver, secure the Vent Sensor connector (J5) clip to the
Burner Housing with a hex head bolt.
Note: this bolt also secures the Burner Housing to
the Heat Exchanger.
5.
Connect the Vent Sensor connector (J5) to the Wiring Harness. Ensure the locking tab is
engaged.
6.
Install Bottom Shell (ref. 5.4.3).
7.
Install Top Shell (ref. 5.4.2).


Back to Top