TM 9-2540-207-14&P
5-57
5.7.7
Burner Housing (Applies to all Design Iterations)
Figure 5.7-12
Burner Housing
5.7.7.1 Removal
1.
Remove Top Shell (ref. 5.4.2).
2.
Remove Bottom Shell (ref. 5.4.3).
3.
Remove Vent Fan Assembly (ref. 5.6.1).
4.
Remove Combustor Assembly (ref. 5.7.1).
5.
Remove the Burner Chamber (ref. 5.7.5).
NOTE: The Burner Wick located inside the Burner Cartridge is made from a
fragile metallic material.
Take great care when handling the Burner
Cartridge so as not to damage the Burner Wicks.
NOTE: IF the wicks are greater than 50% deteriorated, replace the entire
Burner Cartridge (ref. Figure 5.7-9
Burner Cartridge).