TM 9-2540-207-14&P
5-59
Burner Housing (Applies to all Design Iterations) (Continued)
5.7.7.3 Installation
1.
Apply Nickel anti-seize, Loctite 77164 to the threads on the Ignitor Holder.
2.
Install Burner Chamber (ref 5.7.5).
3.
Install Combustor Assembly (ref. 5.7.1).
4.
Install Vent Fan Assembly (ref. 5.6.1).
5.
Install Bottom Shell (ref. 5.4.3).
6.
Install Top Shell (ref. 5.4.2).