TM 9-2540-207-14&P
2-2
2.2
Combustion Air Inlet Connection
For Dual Air Configuration - Refer to appropriate vehicle TM for instructions.
For Single Air Configuration - No Combustion air inlet ducting is required.
2.3 Exhaust Connection
Secure Heater Exhaust Port (Ref. Figure 2-3) to the existing vehicle exhaust duct so it is leak
tight and secured from movement.
Ensure that the exhaust ducting is rated for
continuous
operation
at temperatures of 1,300°F( 593°C).
2.4 Mounting
Attach
two mounting straps on either side of the Top Housing in the locations illustrated in
Figure 2-2.
Figure 2.4-1.
Mounting Strap Locations