REMOVAL - Continued
4.
Open access cover (Figure 2, Item 10) in upper container half (Figure 2, Item 3) and remove desiccant bags
from access port (Figure 2, Item 8). Discard desiccant.
3
10
8
9
MAINT_016
Figure 2.
Container and Nonmetallic Seal.
END OF TASK
INSTALLATION
NOTE
Class 1 desiccant.
1.
Install Class 1 desiccant through access port (Figure 2, Item 8) in upper container half (Figure 2, Item 3) and
screw access cover (Figure 2, Item 10) onto port.
WARNING
Never crawl under equipment when performing maintenance unless equipment is securely
blocked. Keep clear of equipment when it is being raised or lowered. Do not allow heavy
components to swing while suspended by lifting device. Exercise caution when working
near a cable or a chain under tension as equipment may drop or shift. Failure to comply
may result in injury to personnel.
2.
Inspect container nonmetallic seal (Figure 2, Item 9) for cuts, cracks, or other damage. Discard nonmetallic
seal if unserviceable and install a new nonmetallic seal.
TM 9-2815-205-24
0010