TM 9-2815-205-34
(a) Pump 1, 1, 1 trichloroethane solution through oil cooler to remove carbon and sludge.
WARNING
Dry cleaning solvent P-D-680 is toxic and flammable. Wear protective goggles
and gloves and use in a well-ventilated area. Avoid contact with skin, eyes, and
clothes. Do not breathe vapors. Do not use near open flame or excessive heat.
The flash point is 100-138°F (38-50°C). if you become dizzy while using cleaning
solvent, get fresh air immediately and seek medical aid. If contact with eyes is
made, wash with water and get medical aid immediately.
(b) If oil passages are badly clogged, pump cleaning solvent through oil cooler and flush
thoroughly with clean, hot water.
(2) Oil coolers - water side
strong acids. Wear protective
Cooler cleaning solution is made from two
goggles and equipment. Avoid contact with skin, eyes, and clothing. Always
pour acid into water. Water poured into acid will spatter the acid. If contact is
made, flush area with water and seek medical aid immediately or injury may
result.
(a)
Mix a solution composed of one-fifth hydrochloric acid and four-fifths water. Add 0.5 pound
of oxalic acid for each 2.5 gallons of solution.
3-263
WARNING
1, 1, 1 trichloroethane solu-
tion is toxic. Wear protective
goggles and gloves and use
in a well-ventilated area to
avoid personal injury.
Avoid
breathing the fumes or direct
contact with your skin.
Use
recommended safety equip-
ment as required.