OIL SAMPLING SYSTEM REPLACEMENT (2CA, 2DA)
0070 00
DISASSEMBLY
1. Remove inlet hoses.
a. Place mounting bracket (10) in a vise or other suitable holding device.
b. Remove inlet hose (1) from 90-degree fitting of engine oil sampling valve (11).
c. Remove inlet hose (4) from 90-degree fitting of transmission oil sampling valve (12).
2. Remove outlet hoses.
a. Disconnect engine oil sampling outlet hose (13) from dead end fitting (14) on side of
mounting bracket (10).
b. Disconnect transmission oil sampling outlet hose (15) from dead end fitting (16) on side of
mounting bracket (10).
c. Disconnect opposite end of each outlet hose (13, 15) from straight fitting on each oil
sampling valve (11, 12), and remove hoses.
3. Remove sampling valves.
a. Loosen locking nut (17) on each valve (11, 12) and slide valves out of mounting bracket.
17
16
14
15
4
12
11
10
17
1
13
WP 0070 00-2