Engine Governor Maintenance Instructions (Cont)
b.
Installaton.
NOTE
Model B has a manual shutdown cable. Do
steps (1) through (1.2) for Model B.
(1)
Route shutdown cable (1) upward
through opening in cab. Secure using
nut (1.1).
(1.1)
Screw handle (1.2) on shutdown cable (1)
and tighten nut (1.3).
(1.2)
Secure shutdown cable (1) to
transmission shift cable, horizontal tube
of cab, and heater hoses using three ties.
TM 9-2815-224-34&P
(1.3)
Install bracket (1.4), copper washer (2), and screw (3).
NOTE
Do steps (2) through (7) for Model A.
Model B has a manual shutdown
cable. Do steps (7.1) through (7.11)
for Model B.
(2)
Install bracket (4) to lever (5) with
screw (6) and nut (7). Do not tighten.
(3)
Tighten nut (7) leaving lever (4) loose.
(4)
Aline and install lever (5).
(5)
Tighten screw (8).
Change 2
15-39