MWO 5--2350--262--35--4
3--26
SECTION II INSTALLATION OF HDC PRIMARY MANIFOLD ASSEMBLY,
MANUAL SHUT–OFF VALVE V23, AND LEFT MAIN MANIFOLD PRESSURE
TRANSDUCER T7 -- CONTINUED
3--4 MOUNTING AND INSTALLATION OF HDC PRIMARY MANIFOLD ASSEMBLY --
CONTINUED
NOTE
Step b below applies to Figure 3--12.
b.
Attach primary manifold mounting plate, 12496959, (1) to back of primary manifold assembly (2) with four
locking screws, B1821BH038C100L, (4) and four flat washers, 10910174--3, (3), as shown in
Figure 3--12.
Figure 3--12. Installation of Mounting Plate on Primary Manifold Assembly