MWO 5--2350--262--35--4
3--31
SECTION II INSTALLATION OF HDC PRIMARY MANIFOLD ASSEMBLY,
MANUAL SHUT–OFF VALVE V23, AND LEFT MAIN MANIFOLD PRESSURE
TRANSDUCER T7 -- CONTINUED
3--4 MOUNTING AND INSTALLATION OF HDC PRIMARY MANIFOLD ASSEMBLY --
CONTINUED
NOTE
Steps i through l below apply to Figure 3--17.
i.
Place new angle bracket (lower lateral support bracket), 12496927, (5) in position on hull floor next to left
main manifold (2) as shown in Figure 3--17.
j.
Attach bottom of angle bracket (5) to hull floor using one locking screw, B1821BH050C113L, (6) and one
previously removed flat washer, MS27183--18, (7).
k.
Attach side of angle bracket (5) to side of left main manifold (2) using two locking screws,
B1821BH050C113L, and two retained flat washers, MS27183--18.
l.
Attach lower end of brace (lateral support bracket), 12496924, (1) to new angle bracket (5) using one
screw, B1821BH050C250N (8), five flat washers, 10910174--5, (3) (as shown) and one self--locking nut,
MS17829--8C, (4). Do not completely tighten screw at this time.
Figure 3--17. Installation of Primary Manifold Brace