NOTE
Perform steps 9 and 10 if pipe nipple and quick disconnect coupling have not been installed
on pump.
9.
Apply teflon pipe sealant (Item 3, table B-1) to threads of pipe nipple (21). Install pipe nipple in
outlet port on electric hydraulic pump (22) (see figure B-3).
10. Connect quick disconnect coupling (23) to pipe nipple (21).
11. Attach one end of hose assembly (24) to cylinder support assembly (1) and quick disconnect
coupling (23).
NOTE
Electric hydraulic pump fluid capacity is 3/4 gallon (2.8 l).
12. Fill electric hydraulic pump (22) reservoir with hydraulic fluid (Item 2, table B-1) to the proper
level.
13. Connect electric hydraulic pump (22) to an electrical power source.