TB 9-1000-234-13
B-9
B-3
Removal
WARNING
Ensure all hydraulic pressure has been released before disconnecting hose assembly to
avoid injury to personnel.
NOTE
Before disconnecting hose assembly, place a suitable container below end being
disconnected to catch excess hydraulic fluid. Dispose of hydraulic fluid in accordance with
local regulations.
1. Disconnect hose assembly (24) from cylinder support assembly (1) and quick disconnect
coupling (23) on electric hydraulic pump (22) (see figure B-6).
Figure B-6.