11. Continue routing RCU cable (29) and power harness (28) through clamps (60) and (54).
12. Continue routing RCU cable (29) to RCU/PDA bracket assembly and power harness (28) to the
auxiliary radio power connector location.
13. Route PDA power harness lead over to PDA cradle location.
14. Remove screw (66) and lockwasher (64) securing existing loop clamp and wiring harness to hull.
Retain hardware for re-installation.
15. Install power harness ground lead (65) over existing loop clamp and wiring harness.
Secure with
screw (66) and lockwasher (64).
16. Stow RCU to PDA cable within RCU/PDA bracket assembly and secure it with a tie strap.
17. Tighten all hardware securing all clamps and cables.
Figure 21.
RCU Cable, Power Harness, and RCU to PDA Cable Installation (M577A3 Only)