INSTALL INTERCOM UNIT/MOUNTING BRACKET (M1068A3 ONLY)
1.
Install intercom mounting bracket (37) over drilled holes under horizontal sponson.
Secure with
two screws (39) and lockwashers (38).
TORQUE SCREWS TO 24 LB-FT (32.5 N
·
m).
2.
Install intercom unit (40) to intercom mounting bracket (37).
Secure with two screws (39) and
lockwashers (38).
TORQUE SCREWS TO 24 LB-FT (32.5 N
·
m).
Figure 12.
Intercom Unit/Mounting Bracket Installation