2-53
TB 9-2510-251-13
(10)
Pull rear curtain down tight over rear of armor plate.
(11)
Mark and cut four crosses (8) over the bolts and nuts attaching the center armor plate to
the rear side plates.
(12)
Cut crosses just large enough for nut to push through.
8
2-1.2
Installation of Air Conditioning Kit to M1097A2 with GSIE Add-on-Armor (Cont’d).
b. Install Evaporator and Condenser (Cont’d)
Figure 2-79.
Center Armor Hardware Cutouts
9
10
11
12
Figure 2-80.
Lower Support Bracket
(13)
Attach lower support bracket (9) to evaporator unit “L” brackets using two bolts (10),
flat washers (11), and locknuts (12).