TB-9-2510-251-13

TECHNICAL BULLETIN

OPERATOR AND FIELD MAINTENANCE; INSTALLATION MANUAL (INCLUDING REPAIR PARTS LIST); FOR ADD-ON-ARMOR (AoA) AIR CONDITIONING

AUGUST 2007

  TB-9-2510-251-13 - Page 70 of 624

2-54
TB 9-2510-251-13
(14)
Attach upper clamp brackets.
(15)
Four-door vehicles only:
a. Loosely attach upper clamp brackets (13) to upper support brackets (14) on evaporator
unit (15) with four bolts (16), flat washers (17), and locknuts (18).
16
15
17
14
13
18
2-1.2
Installation of Air Conditioning Kit to M1097A2 with GSIE Add-on-Armor (Cont’d).
b. Install Evaporator and Condenser (Cont’d)
Figure 2-81.
Upper Clamp Bracket
(16) Two-door vehicles only:
a. Remove and discard two upper support brackets from evaporator unit.
Set aside bolts
for future use.
b. Loosely attach upper clamp brackets (19) to evaporator unit (20) with four bolts (21).
21
19
20
Figure 2-82.
Upper Clamp Brackets (Two-Door)


Back to Top